Ecovent R part of a complete range of innovative,flexible products from the HVAC expertsEcovent R DUTIES UP TO 2.5 m3/s RHIGH EFFICIENCY HEAT RECOVER
82d Noise DataDimensions mm SizePhaseMotor Size Voltage Fan SpeedMotor Full Load CurrentSpeed ControlEVX143-11 Phase0.23 kW 230 VAC 3290 rpm1.65 AECFl
9SIZE 1 - EVX143-12c Heating and Controls2d Noise DataTechnical DataAir Volumem3/sMaximumLeaving AirTemp oCMaximum kWOutputWater FlowRate l/sWaterPres
2d Noise DataNote: Data for design guidance only. For full details, outline drawings are available upon request.2a PerformanceSelection Data Unit Siz
SIZE 2 - EVX244-1Technical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve & Actuator KitLPHWHeat
SizePhaseMotor SizeVoltageFan Speed Speed ControlEVX345-11 Phase0.4 kW230 VAC2010 rpm 2.1 A ECFlat PlantroomStacked PlantroomFlat WeatherproofStacked
SIZE 3 - EVX345-1Technical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve & Actuator KitLPHWHeat
2a PerformanceSelection Data Unit Size 4 EVX447-1 Electrical input power (Watts) Air volume flow rate (litres/second)SFP Watts/lit
2c Heating and ControlsTechnical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve & Actuator KitLP
2a PerformanceSelection Data Unit Size 5 EVX549-3 Electrical input power (Watts) Air volume flow rate (litres/second)SFP Watts/lit
SIZE 5 - EVX549-317Technical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve & Actuator KitLPHWHe
Why choose VESVES has been supplying products for the HVAC industry for over 40 years, and have the in-depth knowledge and resources to provide so
18 ECOVENT R Duties up to 2.5 m3/s 50mm double skinned case construction to BS EN 1886, plantroom or weatherproof, at or stacked. Plug-fan and inver
19Energy ControlIntegrated energy meter for actual energy consumption and saving calculations is optionally supplied to display real time information
2a PerformanceSelection Data Unit Size 6 EVX616-3 Electrical input power (Watts) Air volume flow rate (litres/second)SFP Watts/lit
2c Heating and ControlsSIZE 6 - EVX616-321Technical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve &
22Dimensions mm SizePhaseMotor Size Voltage Fan Speed Speed ControlEVX717-33 Phase3 kW 400 VAC 2250 rpm 6.4 A InverterUnit TypeA B C D E F
2c Heating and ControlsSIZE 7 - EVX717-323Technical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve &
2a PerformanceSelection Data Unit Size 8 EVX819-3 Electrical input power (Watts) Air volume flow rate (litres/second)SFP Watts/lit
2c Heating and ControlsSIZE 8 - EVX819-3Technical DataMaximum kWOutputWater FlowRate l/sWaterPressure kPaCoilConnectionSize BSPControl Panel Valve &am
26Save energy and costs with BlueSense ControlsDemand ventilation solutions.BlueSense philosophy combines intelligent control technologies with energ
27BlueSense Includes an Extended Warranty f 3 years with BlueSense packages. f 5 years with BlueSense package and Post Installation Commissioning.Plea
1 Pre-wired Controls & Isolator The unit is pre-wired to an integral controls package or isolator to reduce onsite wiring requirements.‘Plug &am
28Ecovent RControlsEnergyControlBlueSense Intelligent ControlEnergy saving packages combine intelligent technologies with energy saving products, serv
29Airflow CommissioningThe unit air volume can automatically be commissioned when purchased with a control panel. This is completed by measuring the p
30Ecovent R Controls - Extended FeaturesCPB & CPC RangeThe Ecovent unit with integrated controls is specically designed for use in heat recovery
Flat Pack Crane Lifts Site Assistance=31Site Assistance By Specialist Site ServicesVES has an accomplished Site Services division; Ecovent units ca
32Ecovent R High Efficiency Heat Recovery Units1.1. GeneralA. Provide a heat recovery air handling unit to meet the performance and conguration as i
Why choose VESVES has been supplying products for the HVAC industry for over 40 years, and have the in-depth knowledge and resources to provide so
Ecovent R part of a complete range of innovative,flexible products from the HVAC expertsEcovent R DUTIES UP TO 2.5 m3/s RHIGH EFFICIENCY HEAT RECOVER
2Ecovent unit with integral controlsEC fan - with full control Sensor optionsThe sign of energy saving products, services and expertiseFor more inf
3High Efficiency Heat Recoveryf Low energy / high efficiency fans.f Low SFPs to achieve L2 Building Regulations.f High efficiency plate heat
4VES Ecovent range provides comprehensive heat recovery units to suit a variety of applications.Selecting Ecovent units has been made easy, through
5Ecovent R Performance4Specify bespoke options for Ecovent R products Page 31As well as offering a wide range of standard Ecovent units VES is
6 ECOVENT R Duties up to 1.5 m3/s 25mm double skinned case construction, plantroom or weatherproof, at or stacked. EC fans with integrated control,
7Choose duty up to 1.5 m3/s or 2.5 m3/sSpecify your chosen unitAdd control packages for performance and efficiencyPages 26-30Specify bespoke option